Pages Menu
Categories Menu

Posted in Boiler Controller

Model 150 Boiler Controller

1269089 Model 150 Boiler Conductivity ControllerThe Model 150 uses the latest in microprocessor capability, giving the user a high level of application flexibility.  Multiple inputs and very easy setup characterize this new technology. 

 

This controller can be used in the Continuous Sample, Sample/Cycle, or Sample/Hold modes to control the boiler water conductivity.

 

PART NUMBER 1269089 SHOWN

Boiler Water Treatment Controller

 

150 CUTSHEET                                                 150 MANUAL

 


 

FEATURES

  • Use this Controller for conductivity control of boilers.  It can be used for Continuous Sample, Sample/Cycle, or Sample/Hold control of boiler conductivity.
  • Removable power cord and receptacles for simple conduit installations.
  • One (1) water meter input, conductivity input, flow switch input, and 4-20 mA output are all standard features.
  • Designed with a single circuit board for better reliability and lower cost.
  • Large open shallow enclosure for easy wiring.
  • The enclosure is rated NEMA 4X.
  • Power selector switch for 115 or 230 vac operation.
  • Heavy-duty stainless steel domed numeric keypad and illuminated graphical display allow for quick and easy programming.  Steel domed switches improve the tactile sensing and life expectancy of the keypad.
  • LED indicators for power, alarm and relay status.
  • The display is lit by two LEDs when any key is pressed.
    • Easy to program, the Model 150 Controller uses an intuitive menu and a numeric keypad for programming.
    • No add-on options.  Flow switch input, 4-20mA output, and three boiler conductivity control methods; Continuous Sample, Sample/Cycle, and Sample/Hold are standard.
    • Single circuit board design improves reliability.
    • Multiple methods of chemical feed for application flexibility.

 

BENEFITS

  •  Easy to program, the Model 150 Controller uses an intuitive menu and a numeric keypad for programming.
  • No add-on options.  Flow switch input, 4-20mA output, and three boiler conductivity control methods; Continuous Sample, Sample/Cycle, and Sample/Hold are standard.

  • Single circuit board design improves reliability.
  • Multiple methods of chemical feed for application flexibility.

 

SPECIFICATIONS

 

Conductivity Range

100-10,000 µS

Water Meter Input

Contact Head, Paddle Wheel ,

Conductivity Sensor

2-Electrode

 

Or Turbine

Conductivity Resolution

± 10 µS

Timer

Max Blowdown Time Exceeded,

Accuracy & Repeatability

± 1%

 

Relay Time Exceeded

Deadband/Setpoint

Adjustable

Output Signal

One 4-20 mA, non-Isolated

Auto/Manual Outputs

Menu Selectable

 

Powered Output

Output Relays

2 Selectable use

Relay Ratings

3A Each, 10A Total

 

1 for Blowdown

Power

120/240 VAC 50/60 Hz

Keypad

16 Tactile Push-Buttons

Ambient

32°-120°F (0-49°C)

Display

16 X 2 Character

Enclosure

NEMA 4X, ETL

 

 

 

 

 

Ordering Options

 Boiler System Options

 

1168374_SR2_060301 1167244 Union shown with plates 1268608_MBV1_060622

1168374 SR2

Boiler Water Sensor with

20 Ft Cable and Conduit Elbow.

 3/4 INCH NPT Connectio

1167244 Orifice Union

1/2 INCH NPT 

Orifice Plates, ½ in NPT

11663541/8 inch opening

1166355 1/16 inch opening

1268608 MBV1

1/2 INCH NPT Motorized ball valve

OR

1268614 MBV2

3/4 INCH NPT Motorized ball valve

 

 

Ordering Information

 

PART NO.         CONDUCTIVITY BOILER WATER CONTROLLER ONLY   

1269089            150 Controller only, no sensor

 

PART NO.         CONDUCTIVITY BOILER WATER CONTROLLER SYSTEMS     

  The Following Systems Include Sensor and Plumbing Assemblies

 1269092            150, SR2, 1/2 Union, Orifice plate, MBV1

1269260            150, SR2, 3/4 Union, Orifice plate, MBV2

1269093            150, SR2, PLKT

                                                                                                                                                       

PART NO.         BOILER OPTIONS (AND/OR REPLACEMENT PARTS)    

1168374            SR2, 2-electrode boiler sensor, conduit elbow, and 20 ft cable

1229843            SR2HD, 2-elec harsh duty sensor, conduit elbow, and 20 ft cable

1166355            Orifice Plate, ½ inch NPT, 1/16

1166356            Orifice Plate, ½ inch NPT

1166354            Orifice Plate, ½ inch NPT, 1/8

1167972            Orifice Plate, ½ inch NPT, 3/8

1167244            Orifice Union, ½ inch NPT

1167245            Orifice Union, 3/4 inch NPT

1268608            MBV1 ½ inch NPT Motorized ball valve

1268614            MBV2 3/4 inch NPT Motorized ball valve

1167295            PL5, ½ sample/cycle plumbing assembly

1168601            PL575, ¾ sample/cycle plumbing assembly

1167297            PL6, ½ continuous plumbing assembly

1167296            PL675, ¾ continuous plumbing assembly

1167520            GV, Globe valve with Position Indicator

1269395            GV, Globe valve without Position Indicator

1233981             PLKT Plumbing Kit, Sample/Cycle and continuos sample kit  

                        Includes unions, orifice     plates, cross, tee, and manual block

                        valve only.  Does not include piping.

 

PART NO.         REPLACEMENT SENSOR        

1167162            2 electrode boiler sensor

1229841            2 electrode harsh duty boiler sensor