Cooling tower · Boiler · Condensate
Model 1575e water treatment controller
Versatile, capable water treatment controller for conductivity, pH, or ORP control.
- 3 + 1relays: three selectable, one blowdown
- 2water meter inputs (contact head, paddlewheel or turbine)
- 4-20 mAinput and output standard
- NEMA 4Xenclosure, ETL listed
95% of Lakewood products ship within 2 days of your order.
A controller that has proven itself for years
The 1575e has a long record as a bulletproof controller. Configure it for cooling tower, boiler, or condensate operation, and set each relay for setpoint control, water meter, percent of blowdown, or percent of time. Up to twelve scheduled feeds can be configured, giving you excellent control of your system.
- Easy to program with the Lakewood plain English, intuitive, and user-friendly menu interface.
- Can be used in boiler, cooling tower, or condensate applications when used with the appropriate conductivity sensor.
- Single circuit board design improves reliability.
- No add-on options. 4-20 mA output and feed schedule clock features are standard.

Specifications
| Type | Model 1575e |
|---|---|
| Includes | Optional sensor and plumbing configurations |
| Output relays | 3 selectable use and 1 blowdown relay |
| Flow switch | Flow switch input |
| Water meter | 2 water meter (contact head, paddle wheel or turbine) inputs |
| Analog input | 1 non-isolated internally powered 4-20 mA input |
| Output signal | 1 isolated or non-isolated optionally powered 4-20 mA output for conductivity |
| Mounting plate | Optional mounting plate |
| Drum switch | 2 digital contact drum switch inputs |
| Temperature compensation | 500 NTC, none |
| Ambient temperature | 32° to 120°F (0° to 49°C) |
| Sensor type | 2 electrode conductivity sensor |
| Conductivity resolution | ±10 µS (conductivity below 5000 µS), ±100 µS (conductivity above 5000 µS) |
| Accuracy and repeatability | ±1.0% |
| Deadband / setpoint | Programmable |
| Enclosure | NEMA 4X, ETL |
| Timer | Max. blowdown time exceeded, relay time exceeded |
| Power | 120/240 VAC 50/60 Hz |
| Relay ratings | 3A each, 10A total |
| Usage | Water treatment conductivity, pH or ORP control |
Features
- Removable power cord and receptacles for simple conduit installations.
- Scheduled feed, which can use three relays for biocides or other chemicals.
- 2 water meter inputs, 2 drum switch inputs, conductivity input, a flow switch input, a 4-20 mA output, and a 4-20 mA input are all standard features.
- The 4-20 mA input can be used with a transmitter for one of the following: remote conductivity, makeup conductivity, pH, ORP, percent, pressure, milliamps, flow rates, or traced chemistry control. This transmitter can be added in the field.
- Designed with a single circuit board for better reliability and lower cost.
- Large open shallow enclosure for easy wiring.
- Ball valve delay feature allows accurate control of motorized ball valves.
- Heavy-duty stainless steel domed numeric keypad and illuminated graphical display allow for quick and easy programming. Steel domed switches improve the tactile sensing and life expectancy of the keypad.
- LED indicators for power, alarm and relay status.
Plumbing
| Limit | Cooling tower | Boiler |
|---|---|---|
| Max pressure | 140 psi (9.65 bar) @ 100°F | 600 psi (41.3 bar) |
| Max temp | 140°F (60°C) | 486°F (252°C) |
| Min flow | 1 gpm (3.785 Lpm) | – |
Used in
Cooling towers Boilers Commercial and industrial HVAC Healthcare and institutional facilities Data centers