
Boiler · Cooling tower · Condensate
Model 3175e conductivity controller for boilers and cooling towers
Touchscreen conductivity controller for boilers and cooling towers, with the menu water treaters already know from the 1575e.
- 7 incolor capacitive touchscreen
- 4 + 1relays: four selectable, one blowdown
- 2water meter inputs
- 50-10,000 µSconductivity range
95% of Lakewood products ship within 2 days of your order.
Accurate conductivity control with a touchscreen
The Model 3175e conductivity controller is designed to provide accurate, reliable control of water chemistry for both boilers and cooling towers. Its fast, responsive 7-inch touchscreen makes setup quicker than a keypad.
We kept the familiar navigation and configuration from the Model 1575e, 140, and 150 controllers that water treaters know. Configure it for cooling tower, boiler, or condensate applications with the appropriate conductivity sensor, set relays for setpoint control, water meter, percent of blowdown or percent of time, and schedule up to 12 feeds. A standard secondary input may be used to control ORP or pH.
- Reliable circuitry that has been proven for two decades to accurately control your water chemistry.
- User-selected relay options for a high level of application flexibility.
- The same menu interface as the 1575e, so there is nothing new to learn.
Specifications
| Model | 3175e |
|---|---|
| Conductivity range | 50-10,000 µS |
| Conductivity sensor | 2 electrode |
| Conductivity resolution | ±10 µS (conductivity below 5000 µS) / ±100 µS (conductivity above 5000 µS) |
| Temperature compensation | 500 NTC, none |
| Accuracy and repeatability | ±1.0% |
| Deadband / setpoint | Programmable |
| Auto / manual outputs | Menu selectable |
| Interface | 7 inch capacitive touchscreen |
| Drum switch inputs | 2 digital contact inputs |
| Water meter inputs (2) | Contact head, paddle wheel, or turbine |
| Timers | Max. blowdown time exceeded and relay run time exceeded |
| Output signal (1) | 4-20 mA, isolated or non-isolated optionally powered output for conductivity |
| Input signal (1) | 4-20 mA, non-isolated internally powered input for conductivity |
| Output relays | 5: 4 selectable use, 1 blowdown |
| Relay ratings | 3A each, 10A total |
| Power | 120/240 VAC 50/60 Hz |
| Ambient | 32° to 120°F (0° to 49°C) |
| pH or ORP sensor | Solution ground, single ended, or signal differential |
| pH or ORP resolution | 0.01 pH, 1 mV for ORP |
Features
- 7-inch color touchscreen display.
- Scheduled feed, which can use four relays for biocides or other chemicals.
- Five output relays: one typically used for bleed/blowdown, plus four chemical feeds.
- Two water meter inputs, two drum switch inputs, one conductivity input, one flow switch input, one 4-20 mA input and one 4-20 mA output.
- The 4-20 mA input can be used with a transmitter for one of the following: remote conductivity, makeup conductivity, pH, ORP, percent, pressure, milliamps, flow rates, or traced chemistry control. This transmitter can be added in the field.
- Removable power cord and receptacles for conduit installations. Enclosure is rated NEMA 4X.
- Single circuit board for high reliability and lower cost.
- Large shallow enclosure for easy wiring.
- Ball valve delay feature allows accurate control of motorized ball valves.
- Onboard selector switch for 120 or 240 VAC power.
- Indicators for power, alarm, and relay status.
Downloads
The 3175e cut sheet and manual are being updated. Call 800-228-0839 for a copy.
Often ordered with
Related blog posts
Where to buy
Get the Model 3175e from a Lakewood partner
Your partner quotes, configures and supports the controller on site. Questions about a Model 3175e you already own? Call 800-228-0839, Mon to Fri, 7:30 am to 4:30 pm Central.


